Ask Daniel Your Own Question
Daniel
Daniel, Home Appliance Technician
Category: Appliance
Satisfied Customers: 16625
Experience:  20+ yrs. experience in white goods repair. NVQ Level 2 electronics manufacturers training courses.
15468697
Type Your Appliance Question Here...
Daniel is online now

Wiring hallmark energy regulator 6in ring = black= blue =

Customer Question

wiring for creda hallmark energy regulator 6in ring brown = black= blue = red =
Submitted: 1 year ago.
Category: Appliance
Expert:  Daniel replied 1 year ago.

Hi

Can you post the model number of the appliance please.

Also is it you are replacing the regulator and the one you have now is different to the one thats on yours?

If so what the part number of the switch you have?

Regards

Customer: replied 1 year ago.
model no 49502 creda cooker. part no of switchele4117
Customer: replied 1 year ago.
no sure of part no of switch.
Expert:  Daniel replied 1 year ago.

Thats fine.

Now how many wires do you have?

Can you post a picture of the wiring on the old switch?

Customer: replied 1 year ago.
4 wires as follows, brown, black, blue, red. old switch thrown out.
Customer: replied 1 year ago.
if I could post a picture of the wiring on the old switch, I would not be asking you about the wiring.???
Expert:  Daniel replied 1 year ago.

Ok basically the wiring conversion is as follows.

P1= Is the live feed in.

4= is the neutral feed

2= is the load which is the feed to the heater plate.

S2 or pilot= is the pilot light whichs is the mains light on the control.

Now to work it out you need to follow the wiring on this.

To find the pilot light will be easy as follow the wires to the light.

As to the live and neutral feed one would assume the live is the brown and the blue is the neutral.

So this just leaves the load feed to the heater which is the other wire which will be either the black or red wire.

The reason i ask for a picture was because i thought it was a conversion switch which is different from the old one.

So thats the wiring for this so its a case of following the wiring to see which is which as the wiring diagrames on these dont list the colour of the wires im afraid.

Let me know how it goes.

Customer: replied 1 year ago.
this is the wiring that I did to the energy reg as follows. brown =P2 black= S1 blue =2 red=P1
Expert:  Daniel replied 1 year ago.

The wiring i listed above is for the regulator you have just brought.