I have an old Creda cooker Modle 40041 the old energy

Resolved Question:

I have an old Creda cooker Modle 40041 the old energy regulater has been replaced with a 31ER1HT single circuit regulator do you have a wiring diagram for it
Submitted: 9 months ago.
Category: Appliance
Expert:  Michael replied 9 months ago.

Hi, is the new regulator the same as the old

Tech Michael

Expert:  Michael replied 9 months ago.

ALso the regulator shouldnt have wires, but the thermocouple protection circuit would.

Customer: replied 9 months ago.
No it is a new type and there is no wires coming from it.It is the wires coming from the cooker into the regulator I need to know
Expert:  Michael replied 9 months ago.

Hi thanks, ***** ***** to send me a model and make of the new regulator or a pic, you may not need the wires, or you may have an incomparable regulator? I cant tell until I see the new regulator and old one.

Expert:  Michael replied 9 months ago.

You can send pics right here

Customer: replied 9 months ago.
It is a Energy Regulator Diamond H41ER110BI on the old one there is three cables going into it one into line in one into load and the other into neutral on the new one there are 6 connecters S1 S2 P1 P2 2 4A which cable goes into what connecter
Expert:  carlday1 replied 9 months ago.

Hi,

My name is ***** ***** I will help with your question. The wiring for the new simmerstat is

S1 - Signal/Pilot (neon) input ---- not needed

S2 - Signal/Pilot (neon) output ---- not neeeded

P1 - Live In

P2 - Neutral In

2 - Live Output

4 - Neutral Output ----- not needed

I hope this helps