Ask Andrew Smith Your Own Question
Andrew Smith
Andrew Smith, Plumber
Category: Home Improvement
Satisfied Customers: 3629
Experience:  City and Guilds Qualified plumber
46681511
Type Your Home Improvement Question Here...
Andrew Smith is online now

I have a c24 betacom combi boiler with flashing flames fault.

Customer Question

I have a c24 betacom combi boiler with flashing flames fault. The boiler light up for 10 seconds then goes of then led flashing on 90 on front panel. I have check condensation trap just in case it block it clear and clean all air pressure switch tubes going to fan. I thinking gas valve?
Submitted: 3 years ago.
Category: Home Improvement
Expert:  Andrew Smith replied 3 years ago.

Andrew Smith :

It sounds like you have no ciculation

Andrew Smith :

Can you find your pump?

JACUSTOMER-amaur0no- :

Already fix it

Andrew Smith :

Are you saying that your problem is sorted?

JACUSTOMER-amaur0no- :

Yes thank you for your time it was the sensors on the little blue cap on the condensation trap in the boiler they were shorting out

Andrew Smith :

Well found.

Andrew Smith :

Thanks for letting me know