Ask Andrew Smith Your Own Question
Andrew Smith
Andrew Smith, HVAC Technician
Category: HVAC
Satisfied Customers: 3629
Experience:  Heating and Controls engineer
46681511
Type Your HVAC Question Here...
Andrew Smith is online now

we have a glow worm back boiler it is about 18 years old it

Resolved Question:

we have a glow worm back boiler it is about 18 years old it is an inset BBU 40. the problem we have is that when it attempts to light it keeps tripping out it is now not coming on at all. we have replaced the circuit board and the gas valve and it has been serviced twice.
Submitted: 3 years ago.
Category: HVAC
Expert:  Andrew Smith replied 3 years ago.

XXXXX XXXXX :

it could be one of the cheapest parts - the ignition electrode and lead - has this been changed?

Customer:

hi andrew

Customer:

no we don't think has been changed, we changed the circuit board and ignition lead, combustion products safety device, the gas valve was changed a few years back apparently,

XXXXX XXXXX :

There could be a small crack that may let it light but will not let the mV back to the PCB to tell it is lit

Andrew Smith and other HVAC Specialists are ready to help you

Related HVAC Questions