I would like to connect my underfloor heating system to my

Customer Question

I would like to connect my underfloor heating system to my vokera ch boiler its the electric side of it, the plumping side is ok and working when the UDF heating wants hot water a want it to switch the boiler on we do it manual just now
Submitted: 4 years ago.
Category: Plumbing
Expert:  Andrew Smith replied 4 years ago.

Andrew Smith :

If you put a 2 port valve on the heating about 2 foot below the boiler, then tee off above it and then put a motorised valve on that branch

Andrew Smith :

Let the room stat control the 22mm main supply and let the underfloor stat control the teed in circuit and fee the floor circuit from that

Andrew Smith :

Wire it as an S plan

JACUSTOMER-p30uv5fy- :

a need to talk to you about my setup I understand what you mean in your answer

Andrew Smith :

I am back on now