I have a 2 year old baxi Duo Tec. Today the water stopped

This answer was rated:

Hello I have a 2 year old baxi Duo Tec.
Today the water stopped running out all of the hot water taps in house.
Hi , is your boiler a conventional boiler with a separate hot water tank.?
Customer: replied 2 years ago.
No it's a Baxi duo tec 40 combi
Hi , have you had any work done to it in the last couple of days?
Customer: replied 2 years ago.
No just altered water pressure via fixed filling loop
Hi you may have turned the hot water isolation valve off instead of the filling loop valve. Easily done
Customer: replied 2 years ago.
So which is the hot water isolation valve please
Hi , should be second pipe across from the left. Check that the isolation slot is inline with the pipe
Customer: replied 2 years ago.
Hi, looking straight at the boiler there is the yellow gas valve then left is the main cold water inlet valve with smaller valve in pipe loop
To the left of that Central heatING return with main valve and small valve in pipe loop
Hi , yes it will be the main cold water inlet valve isolation valve
Customer: replied 2 years ago.
Ok got and that's working thanks
Your welcome . Would you please mind rating your answer , thanks
Plumberpro and other Appliance Specialists are ready to help you
Customer: replied 2 years ago.
Sure how do I do that
I'm not sure. I think it comes up somehow.