How JustAnswer Works:
  • Ask an Expert
    Experts are full of valuable knowledge and are ready to help with any question. Credentials confirmed by a Fortune 500 verification firm.
  • Get a Professional Answer
    Via email, text message, or notification as you wait on our site. Ask follow up questions if you need to.
  • 100% Satisfaction Guarantee
    Rate the answer you receive.
Ask Plumberpro Your Own Question
Plumberpro, Plumber
Category: Plumbing
Satisfied Customers: 634
Experience:  Heating and plumbing answers. 20 years experience
Type Your Plumbing Question Here...
Plumberpro is online now


This answer was rated:

BIASI 28s COMBI BOILER; HOT WATER NOT FIRING UP, central heating works, water pressure, gas supply and electric supply ok. Running hot water taps, gives small amount of hot water when CH is on. Why is this happening?
Hi , take the car off and run hot water tap. Check that the pin on the diverter valve is making the microswitch
Customer: replied 2 years ago.
Pin is making contact in the microswitch
Customer: replied 2 years ago.
I have checked the diaphragm and it is sound, but there was a lot of rust pieces in there so cleaned out and reassembled. About to refill system with water
Hi, maybe fault is the microswitch. Try pushing the microswitch in with a a few driver and see if the burner lights. If it does then that leaves the hot water thermistor
Customer: replied 2 years ago.
Just getting back, there was a bigger problem. The boiler was giving off a burning smell, so quickly switched of electrics to boiler.The burning was coming from the PCB, but tested the pin before shut down and it made no difference.Scared to plug boiler back into the electrics. Do you think it needs a new PCB?
Hi , yes if the pcb was giving off that smell, but for the cost of a pcb it might be worth considering a new boiler as there could be something shorting the board.
Customer: replied 2 years ago.
I had a look at the board and the burnt area seem to be near the lock out light.I have switched electric to boiler back on, but boiler still locking out, pump starts but then stops.Cannot smell any more burning.
Hi , if there are burn marks on the board I think it will definitely need replacing. There are places that do reconditioned ones.
Customer: replied 2 years ago.
Thanks for your advice. I had a heating engineer to have a look at the boiler. He agrees with you that the pcb needs changing. Part has been ordered.
Ok , all the best . If happy with my answer would you mind rating g it please, thanks
Customer: replied 2 years ago.
PCB replaced. Boiler fires up and central heating now working again, but hot water not working. With knobs set to central heating and hot water, when hot water tap is opened boiler flames shut down and water runs cold.Replaced microswitch on diverter, but problem continues. Could the problem be with another heat sensor?
Hi , sorry to hear that , yes it could be the hot water temperature sensor/thermistor. They are relatively cheap and easy to change.
Plumberpro and other Plumbing Specialists are ready to help you
Customer: replied 2 years ago.
I can replace the hot water thermistor. Thanks.
Customer: replied 2 years ago.
Thanks to your advice, I replaced the hot water thermistor and boiler is now giving hot water in demand. Central heating system also working. Happy customer
Thats great. Well done .Please dont forget to rate me , thanks